Treatment Of Failure To Separate The Capsule Of The Automatic Filling Machine

Jan 03, 2023

Leave a message

 Fully automatic filling machine is a kind of intermittent operation multi hole plug metering fully automatic closed filling equipment, which can automatically complete various processes such as bag sowing, bag separation, filling, waste bag removal, bag locking, finished product export, particle filling, etc. It has the advantages of reliable positioning, accurate loading, and high yield. It is suitable for automatic filling of powder and pellets capsules. It has passed the provincial technical appraisal and meets the GMP standard.
What should we do when the capsule shell cannot be separated when we operate the automatic capsule filling machine?
The full-automatic capsule filling machine is operated by touch panel, frequency conversion and speed regulation. Its action is flexible, the filling dosage is novel, the shape is beautiful, and the operation is convenient. It can take the initiative to complete the capsule positioning, separation, filling and other actions, reduce labor intensity, and improve the output power. Suitable for filling all kinds of capsules, whether domestic or imported. It is an economical and practical equipment for filling capsule drugs in pharmaceutical profession.
1. The capsule itself needs to be replaced.
2. The vacuum is too small. There are many factors that cause the vacuum to be too small. If the vacuum pump is a problem, find a mechanic to repair or replace the vacuum pump. The trachea separated from the vacuum pump connecting with the capsule is cracked, and the trachea is replaced. The filter membrane of the vacuum pump is blocked. Clean the filter membrane. Other factors may be too small water flow, so we need to replace a larger water flow pipe. Of course, we should find out the factors according to the situation. Here are just a few examples.
3. The gap between the module and the capsule separator is too large, which can adjust the height of the capsule separator or the module, or the elastic rod in the module is in doubt. Of course, this needs analysis. Zui is prone to doubt if the powder is too thin or sticky.
4. The module is not correct. Use the debugging rod to adjust the module until it is in the active position.
5. If the powder is too sticky and blocks the module, the module should be cleaned.