Common Fault Diagnosis And Solution Of Liquid Filling Machine

Apr 13, 2022

Leave a message

The use of the liquid filling machine has brought great convenience to the production operation of our enterprise. Its high efficiency work is obvious to all, but the machine will inevitably have more or less problems. Today, Xiaobian brings you a liquid filling machine. Common faults and solutions.


Failure problem: If we are filling large sizes, the material tank is insufficiently replenished, resulting in unstable liquid level. Cause filling inaccurate.


Solution: You can increase the amount of feeding material or close the small ball valve again, and reset the filling time (longer the filling time) to slow down the filling speed to solve the problem.


Trouble: If the digital dial or unit is adjusted, the time does not change.


Solution: At this time, turn off the power and turn it on again.


Fault problem: If the material tank is replenished enough, the liquid level is stable, and the filling amount is insufficient and inaccurate.


Solution: There may be debris blocking the filling channel. Check the inlet of the trough or in the filling nozzle, and clean up the debris.


Troubleshooting problem: If you encounter the problem of dripping after closing and stopping the liquid filling.


Solution: 1. The orifice of the filling nozzle may be damaged. You can take out the filling nozzle and trim the orifice. The diameter of the orifice should not be greater than 7.5mm. After repairing the aperture, lightly smooth the aperture plane on the water abrasive paper.

      

              2. The ball valve in the filling head is damaged and needs to be replaced.


Troubleshooting: If the material is not filled after touching the injection switch, the digital indication LED of the time relay does not flash.


Solution: It is possible that the injection switch is damaged or the base of the time relay is loose. Replace the injection switch of the same type or press the base of the time relay tightly.

Troubleshooting: If the material is not filled after touching the material injection switch, but the digital LED indicator of the time relay flashes.


SED-6GX1

Solution: 1. Check whether there is air pressure or whether the air pressure is too low. If it does not meet the air pressure requirements, we must adjust it in time, and then start the machine to observe.


              2. If the air pressure meets the requirements, it may be that the solenoid valve coil is damaged or the pneumatic valve core is stuck by stolen goods. You can unplug the power supply, open the board, and use the object to rotate or press the button next to the corresponding solenoid valve coil.


If the valve can be reversed Action means that the solenoid valve coil is damaged. If the direction cannot be reversed, the valve spool is stuck, and the solenoid valve coil can be replaced or the valve can be decomposed for repair.


    As long as we pay attention to the maintenance of the liquid filling machine and carefully observe the common small problems, we can solve the emergency treatment by ourselves. 


They will not become an obstacle to our operational efficiency until the after-sales maintenance personnel of the manufacturer come over to confirm further. of.


Application of Liquid Filling Machine

Widely used in filling milk, wine, drinking water and other low-viscosity non-gas liquids, as well as various food and beverages (such as tea drinks, soy sauce, wine, vinegar, etc.), medicines (alcohol, disinfectants, hand sanitizers), chemicals, Pesticides (containing acids, bases, organic solvents or dimethylbenzene) can fill various liquids in industry.

SED-4gx