During the filling process of the automatic capsule filling machine, the movement of the capsule is dependent on the indexing box for intermittent and discontinuous rotation. The filling volume of the capsule is mainly determined by the volume of the metering disc hole.
The hollow capsule is in the capsule hopper, the main board of the automatic capsule filling machine moves up and down, the capsule enters the capsule guide groove by its own gravity, and then the horizontal fork and the vertical plug make the capsule cap upward and the capsule body downward into the upper and lower modules. , and the capsule body and capsule cap are separated under the action of vacuum suction, and then the module enters the powder filling station.
The sensor in the powder-containing ring of the automatic capsule filling machine controls the screw feeding rod above it, and the powder is added to make the height of the powder in the powder-containing ring constant. While the metering disc of the hard capsule filling machine rotates intermittently, five groups of tamping rods are sequentially tamped in the hole of the metering disc. medicine powder, and at the filling station, push the medicine column into the capsule body. After that, it enters into the capsule rejection, capsule locking, finished capsule discharge, module cleaning station in turn, and then enters a new round of station cycle, and the cycle begins again and again.
The volume adjustment and production are as follows:
(1) Jog the filling part to a very low position, then loosen the lower nut of the handwheel on the filling upper part, and adjust the handwheel. The smaller the amount displayed on the window, the lighter the filling. First, a group of filling rods are adjusted to protrude 1 mm from the lower plane of the metering plate by eye observation, and then fix the nut. The sixth group is adjusted to 1 mm lower than the upper plane of the metering plate, the fourth group is 1-2 mm lower than the fifth group of filling rods, and so on. If the weight is light (one group and the sixth group are not adjusted), the other four groups Fine-tuning is possible.
(2) Enter the manual page, and add the capsule and powder into the capsule bucket and powder bucket respectively.
(3) Click the capsule switch, vacuum pump, click the jog button of the electrical box to make the capsule run 3 stations separately, then click the feeding switch in the touch screen, and add the powder until the sensor turns red.
(4) Enter the automatic page, adjust the frequency to between 40Hz-50Hz, and click the run button. Every time the machine runs for about 10-15 minutes, take the weighing and check whether the weight is stable.
(5) When the machine is running, do not use a brush to clean the dust around the turntable. Do not touch the rotating parts of the machine with your hands, pay attention to personal safety to prevent injury!