Safety Operation Procedure Of Semi-automatic Capsule Filling Machine

Dec 16, 2022

Leave a message

Check whether the equipment and its parts are in good condition, disinfect according to the Sterilization Procedure for Semi automatic Capsule Filling Machine, and select and install the required type of bag conveying assembly, bag sowing series, thimble plate, capsule plate, etc. 


Turn on the air compressor, press it to the automatic adjustment position, and the pressure of the empty disk will be automatically adjusted between 0.5-0.7Mpa. Start the main motor and the vacuum pump motor. When the vacuum gauge indicates 320, install the capsule tray, and move the operating lever to start seeding. 


Set the bag sowing counter to the desired value in advance, and turn the input selection switch to the "contact" position to automatically complete a tray of bag sowing. During operation and suspension, do not arbitrarily turn the reset button on the counter to avoid damaging the internal parts. 


After seeding, rotate the capsule disc by hand for 2-3 cycles to better separate the hollow capsules in the capsule disc. Properly adjust the cock on the round handle of the vacuum filter to maintain proper vacuum, so that the capsules can be easily separated without cracking. Press the control panel selector switch (SA2) to the "Automatic" position, lift or press the powder disk gear lever to rotate the powder disk, and press the panel filling button (SB2) to turn the powder filling hopper to the appropriate position of the capsule disk. 


Adjust the filling counter so that the empty disk can be filled completely. If the filling is not good, adjust the increase or decrease of the counter wheel to solve the problem. During filling, the head and hand should not enter the movement range of the storage materials at will to avoid bruise. 


Capsule locking: align the upper and lower capsule plates, make the thimble plates all enter the holes of the capsule plates, step on the pedal to open the air pressure valve, lock the capsules, and then move the capsules towards the thimble section, so that the capsules are pushed into the finished product tank and flow into the container. During the operation, pay attention to the water level of the steam water separator. If it exceeds the height, drain it in time.


In case of emergency during operation, press the red emergency stop button (SB2) immediately. After troubleshooting, press the selector switch (KA3) to the "Manual" position to reset the counter.