Talking About The Maintenance Of Vacuum Separator Of Automatic Capsule Filling Machine

Nov 16, 2022

Leave a message

The full-automatic capsule filling machine integrates machine, electricity and gas, adopts microcomputer programmable controller, touch panel operation, frequency conversion and speed regulation, and is equipped with electronic automatic counting device, which can automatically complete the positioning, separation, filling, locking and other actions of capsules, reduce labor intensity, improve production efficiency, and meet pharmaceutical and health requirements. 


2500j-b1


This machine is sensitive in action, accurate in filling dosage, and convenient in operation. It is suitable for filling various domestic or imported capsules. It is an economical and practical equipment for filling capsule drugs in the pharmaceutical industry.


The vacuum separator of the vacuum system of the full-automatic capsule filling machine is mainly used to suck the capsule into the upper and lower modules and separate the cap and body during the filling of hard capsules.


 If the cap and body cannot be separated, subsequent filling will not be carried out. Each time the rotary table of the capsule filling machine runs for one station, the machine spindle rotates for one circle, and the vacuum separator of the capsule filling machine moves up and down once under the action of the cam.


If the separation of the capsule cap and body is not smooth, check the gap between the upper plane of the vacuum separator and the lower plane of the lower module. 


If the gap is too large, the vacuum degree of the vacuum system will not reach the vacuum degree required for the separation of the cap and body. If the gap is too small, it is easy to cause a collision to deform the lower module. 


When the position of the vacuum separator needs to be adjusted, use the handle to rotate the main motor shaft of the automatic capsule filling machine to make the vacuum separator rise to the zui high position, loosen the lock nuts at both ends of the adjusting rod under the machine table, rotate the adjusting rod to adjust the height of the vacuum separator, then lock the nut, and use the handle to rotate the main motor shaft to test until it is appropriate. 


The vacuum degree is read on the vacuum gauge on the machine operation panel. If the vacuum is too high, the vacuum degree regulating valve can be properly opened. If the vacuum is too low, the vacuum degree regulating valve can be turned down or closed. 


The filter of the vacuum system of the capsule filling machine shall be opened regularly to remove the blocked dirt, so as to ensure that the vacuum system has sufficient vacuum degree.